Hetzner - DokuWiki
Softwareraid/en
Inhaltsverzeichnis |
Software RAID
Software RAID is when the interaction of multiple drives is organized completely by software.
RAID Level 1 (mirroring) achieves increased security since even if one drive fails, all the data is still stored on the second drive. RAID Level 0 (striping) leads to double the capacity (with two drives) and increased reading spead compared to RAID 1 - but all data will be lost if even one of the drives fails.
Our installimage, which is used to manually install an operating system, can be used to configure the drives in RAID 1 or RAID 0. Also, the software RAID can be combined with LVM.
Servers pre-installed by Hetzner are configured with RAID superblocks (version 1.2) when this is supported by the operating system (so all systems with Grub2 as the boot loader). When installing via VNC it can occur that the installer uses other Metadata versions.
Email notification when a drive in software RAID fails
- Requirement: installed and configured mail server
Debian/Ubuntu/CentOS
Edit /etc/mdadm/mdadm.conf or /etc/mdadm.conf (CentOS) and change the following line:
MAILADDR root
Here a destination address can be specified directly. Alternatively, all emails sent to root can be forwarded to a specific email address using /etc/aliases.
You can also optionally configure the sending email address:
MAILFROM mdadm@example.com
For Debian and Ubuntu it is important that you set "AUTOCHECK" in the file /etc/default/mdadm to "true":
# grep AUTOCHECK= /etc/default/mdadm AUTOCHECK=true
For CentOS, you must enable the check in the file /etc/sysconfig/raid-check:
# grep ENABLED /etc/sysconfig/raid-check ENABLED=yes
openSUSE
Edit /etc/sysconfig/mdadm and add the email address that you want the notification sent to next to the variable "MDADM_MAIL":
MDADM_MAIL="example@example.com"
Removing a software RAID
In order to remove a software RAID you can issue the following commands in the Rescue System:
mdadm --remove /dev/md0 mdadm --remove /dev/md1 mdadm --remove /dev/md2
mdadm --stop /dev/md0 mdadm --stop /dev/md1 mdadm --stop /dev/md2
After that, the drive can be formatted normally again (e.g. with ext3):
mkfs.ext3 /dev/sda mkfs.ext3 /dev/sdb
The result can be checked with:
fdisk -l
The software RAID should be gone.
Then installimage can be used in order to install a new operating system.
If an OS is installed and software RAID is activated on the server, then purely running installimage and installing a new OS without software RAID won't work. The server won't boot in this case.
Guides
- Installing operating systems with installimage incl. software RAID, OS independent
- Replacing a faulty drive in software RAID